HARDWARE SYMPTOM MODEL: 2681202 TIER 1–2 BENCH DIY

Kenmore 2681202: Water Tank Full Indicator

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

LED indicator illuminates, cycle pauses.

02 // Non-Invasive Meter / Bench Verification

Empty the condensate water tank. If alert persists after emptying, inspect condensate pump and sump float switch for lint sludge.

Platform / OEM Cross-Reference: Companion 24-inch 2.2 cu. ft. front-load washer 2641202 shares the same 24" compact stackable platform and stacking kits 26-1202/26-1222.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
Compact AC… Condensate Lift Pump
Must match voltage (120V vs. 240V coil), frequency, and mounting for proper operation.
~$35–$75
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified residential compact ventless condenser dryers replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSEPDMNTCPolypropyleneSiliconeStainless Steel

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Never dry items exposed to gasoline, solvents, or oils.
  • Do not apply heat to foam rubber or rubber-textured items.

Root Failure Mechanism: Condensate Sump Sludge & Pump StallClick to spotlight part ↑

01 // Trigger ConditionLint bypassing the primary filter and mixing with condensate water in the lower sump.
02 // Degradation PhysicsWet lint accumulates to form sludge, jamming the pump impeller or float switch.
03 // Lockout / ImpactPersistent "Water Tank Full" fault (even if tank is empty), cycle interruption, or potential water leakage onto the floor.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Clothes feel slightly warmer/damper at cycle end compared to vented dryers.: Condensing dryers leave fabrics feeling slightly warmer/damper at cycle end until flash-off occurs due to the nature of their heat rejection and moisture removal process. (True fault when: If clothes are consistently wet, not just damp, or if dry times are excessively long, it may indicate a fault (e.g., fouled condenser or sensor).)
False-Alarm Check — Laundry room becomes noticeably warm/humid; cycles take longer than vented 240V dryers.: Ventless condensing dryers reject latent and sensible heat into the room as part of their normal operational physics and inherently have longer dry times than vented dryers. (True fault when: Rapidly degrading dry times or excessive room humidity/heat beyond typical operation may indicate a lint-blocked condenser or insufficient room ventilation.)