FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
EQUIPMENT DOWN? Interactive Bench Isolation & Verified OEM Fix Kit Below
Jump to Fix Kit ↓
HARDWARE SYMPTOM MODEL: DLGX4001W TIER 1–2 BENCH DIY

LG DLGX4001W: tE1 or tE2

⚡ Bench Triage & Meter Telemetry
10 kΩ

01 // Observed Condition

Outlet NTC thermistor open/shorted.

02 // Non-Invasive Meter / Bench Verification

Measure thermistor resistance (~10 kΩ at room temp) and check wiring harness for continuity.

Platform / OEM Cross-Reference: Shares core 7.4 cu. ft. chassis, drivetrain, and gas burner architecture with LG DLGX3901 / DLGX4001B / DLGX4201 series.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
6323EL2001B Outlet Thermistor
Resolves tE1 error when out of spec. Ensure correct resistance curve.
~$15–$25 OEM / ~$8–$15 Generic
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified clothes dryers gas replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:EPDMNTCStainless SteelStainless-Steel

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • LP conversion must be performed by a qualified gas technician.
  • Do not use plastic or vinyl foil ducts for exhaust venting.

Root Failure Mechanism: Outlet NTC Thermistor FailureClick to spotlight part ↑

01 // Trigger ConditionNormal operation with thermal cycling
02 // Degradation PhysicsThermistor element or wiring harness develops an open or short circuit.
03 // Lockout / ImpactInaccurate temperature readings, leading to tE1/tE2 error codes and improper drying cycles (overheating or no heat).

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — FlowSense d80/d90/d95 alerts: FlowSense is a design safety feature that detects exhaust restriction, which can be caused by lint buildup, kinked ducts, or blocked exterior vents. It protects the appliance from overheating and prevents fire hazards. (True fault when: If the ducting is confirmed clear and the lint filter is clean, but the error persists, it may indicate a fault with the FlowSense thermistor or main control PCB.)

Other LG DLGX4001W Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...