FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
EQUIPMENT DOWN? Interactive Bench Isolation & Verified OEM Fix Kit Below
Jump to Fix Kit ↓
EXPLICIT FAULT CODE MODEL: WKG101HWA TIER 1–2 BENCH DIY

LG WKG101HWA: d80, d90, d95 (FlowSense™)

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Dryer exhaust airflow restriction detected, typically due to a clogged external vent or crushed duct.

02 // Non-Invasive Meter / Bench Verification

Clean 4 in. metal ducting from unit to exterior hood.

Platform / OEM Cross-Reference: Shares chassis, Center Control™, washer drivetrain, and ThinQ® platform with WKE100HVA (Graphite Steel electric), differing in finish (White) and 20,000 BTU gas burner / 120V-15A dryer power architecture.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
AGM30045804 Dryer Thermostat & Thermistor Kit
OEM part number ensures correct temperature sensing and safety cutoff. Generic alternatives must precisely match resistance-temperature characteristics.
OEM: ~$25–$45 / Generic: ~$10–$20
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified stacked washer dryer gas replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:BLDCBRASSCast AluminumNTCPTFEStainless Steel

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • LP Gas Conversion must be performed by a qualified gas technician.
  • Shut off both the gas supply valve and 120V power before servicing gas components.

Root Failure Mechanism: Exhaust Blockage / High-Limit TripClick to spotlight part ↑

01 // Trigger ConditionAccumulation of lint in the exhaust ducting.
02 // Degradation PhysicsRestricted airflow causes exhaust temperatures to rise, triggering the high-limit thermostat or FlowSense™ system.
03 // Lockout / ImpactDryer stops heating, extends drying times, or presents error codes. Fire hazard if severe.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Audible gas-valve click followed by soft burner whoosh.: This is the normal sequence of the gas valve opening and the burner igniting, regulated by the thermistor to maintain drum temperature. (True fault when: If the igniter glows but no whoosh is heard (no gas flow), or if the burner fails to light repeatedly, or if a strong gas odor is present.)

Other LG WKG101HWA Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...