LG WM8900HBA: tE (Thermistor) / PE (Pressure Sensor) error codes
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Temperature / Water Level Faults
02 // Non-Invasive Meter / Bench Verification
Check NTC thermistor resistance against temperature table (requires service manual). Inspect pressure hose for pinholes or clogs.
Platform / OEM Cross-Reference: 10-year limited Direct Drive motor part warranty, lifetime drum part warranty, 20–120 PSI water pressure window, and 4-inch rear / 1-inch side installation clearances.
Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN
Role
OEM MPN / Spec
Component & Fitment Notes
Est. Street
Check Stock
Part 1 oem replacement part Isolated Match
4681EA2001T
Drain Pump Motor Assembly Confirm exact connector orientation and mounting via serial suffix. Generic parts must match voltage, frequency, and physical dimensions.
Material / Sensor Nodes:BLDCCast AluminumCast-AluminumEPDMNTCPolypropyleneStainless Steel
Before Ordering Parts: Normal Operation vs. True Fault
False-Alarm Check — CL (Child Lock) display: CL is a normal lock state, indicating the Child Lock feature is active, preventing accidental operation. (True fault when: If the CL indicator cannot be deactivated by the documented procedure (e.g., holding a button for 3 seconds), it may indicate a control panel or UI fault.)
False-Alarm Check — Sud (Excess Suds) display / Extended cycle times: Sud indicates the washer has detected excessive suds, typically from using non-HE detergent or too much detergent. It triggers automatic extra rinse cycles to protect the pump and drainage system. (True fault when: If 'Sud' appears despite using correct HE detergent and dosage, it could indicate a water level sensor (pressure switch) issue or a drain problem.)