FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
EQUIPMENT DOWN? Interactive Bench Isolation & Verified OEM Fix Kit Below
Jump to Fix Kit ↓
HARDWARE SYMPTOM MODEL: BK-888 TIER 1–2 BENCH DIY

Mini BK-888: Fan Runs, No Heat

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Cool air discharged; display normal.

02 // Non-Invasive Meter / Bench Verification

Check if unit is in cool-down/UV-only mode; if heated gear selected, test PTC continuity.

Platform / OEM Cross-Reference: Multi-vendor white-label ODM platform sold under 'Mini', 'Generic', and 'JOMO' labels with identical BK-888 designation.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
Axial thermal fuse (exact… Thermal Cutoff Fuse
Critical to match exact temperature and current ratings for safety and proper operation.
Generic: $1–$3
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified compact portable clothes dryers replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSPTCTRIAC

Failure Physics & Causal Isolation

Root Failure Mechanism: Overheat Cutout Trip / Thermal Fuse BlowClick to spotlight part ↑

01 // Trigger ConditionOperation with restricted airflow (blocked intake or overstuffed bag)
02 // Degradation PhysicsAirflow drop leads to chamber temperature spike, causing the thermal cutout to trip or thermal fuse to blow.
03 // Lockout / ImpactUnit powers off unexpectedly, no heat output, or complete operational failure requiring repair.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Slow Drying on Heavy Fabrics: The 450W PTC thermal output is limited and sized for light garments (t-shirts, underwear, baby clothes), not heavy, dense fabrics which require higher heat and airflow. (True fault when: If light garments also take excessively long to dry, or if the unit is not producing warm air when a heated mode is selected (see 'Fan Runs, No Heat' diagnostic).)