FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: FS-422 TIER 4 LICENSED / SEALED

2X FS-422: Partial Dark Section

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

1–3 adjacent LEDs are out while the rest of the bar remains lit.

02 // Non-Invasive Meter / Bench Verification

Indicates internal PCB branch failure; non-user-serviceable.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
universal aftermarket part
Isolated Match
UL-listed 5V DC … 5V USB Wall Power Adapter
Standard USB-A output, 5V DC nominal voltage, and sufficient current rating (2A-2.4A) to power the kit. UL listing ensures safety compliance.
Generic: $6–$12
Part 2
universal aftermarket part
Isolated Match
3M VHB 4910 / 5952… High-Temp Mounting Tape
High-bond acrylic foam tape suitable for kitchen environments (heat, moisture, grease resistance) and capable of supporting the light bar's weight.
Generic: $8–$15
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified under cabinet linear led strip bar kits replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSSilicone

Failure Physics & Causal Isolation

Root Failure Mechanism: LED Lumen Depreciation / Segment OutageClick to spotlight part ↑

01 // Trigger ConditionSustained thermal stress from enclosed under-cabinet mounting.
02 // Degradation PhysicsElevated LED junction temperatures cause phosphor shift (color change) or accelerated lumen depreciation; thermal cycling can lead to open solder joints or component failure.
03 // Lockout / ImpactReduced light output, color shift, or partial dark sections on the light bar.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Bar feels noticeably warm (35°C–50°C) to the touch.: LEDs and current-limiting components dissipate electrical energy as heat, which is passively conducted through the housing. This warmth is a normal physical process. (True fault when: Hot-to-touch (>60°C) or a burning odor indicates a fault.)

Other 2X FS-422 Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...