Symptom Guide Model: 1046AR

BesLowe 1046AR: Light Does Not Turn On at Night

What this means: Fixture remains completely dark when it should be active (e.g., after dusk, with motion).

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Light stays on continuously at 100% brightness for 6-8 hours. — This is a designed operating mode (Manual Override) that activates when the wall switch is toggled OFF-ON-OFF-ON within 2 seconds. The light will remain on at 100% brightness for 6-8 hours or until dawn.

Verify circuit breaker/wall switch is ON. Test with a known-good E26 bulb. Check photocell for stray light or obstruction. Inspect wire connections (with power OFF).

2

Verified Replacement Parts

#1 Most Likely Fix Generic: $3–$12

E26 Light Bulb

Standard E26 Medium… Copy Part #

Must be E26 base, max 100W. Dimmable LED or incandescent recommended for stable operation in High Mode. Wet/damp rating is advisable for outdoor use.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in outdoor wall lanterns and sconces replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Photocell Sensor Malfunction

What triggers it: Long-term outdoor exposure to UV, moisture ingress, or physical obstruction/damage to the photocell window.

What wears out inside: Degradation of the photocell's light-sensing element or its connection to the control PCB, or persistent blockage of the sensor.

Symptom on machine: Fixture fails to activate at dusk, remains on during daylight, or Manual Override fails to reset at dawn, leading to improper operation and wasted energy.

Internal Sensor Control & Dimming PCB Failure

What triggers it: Exposure to voltage fluctuations, moisture ingress, excessive heat from high-wattage bulbs, or long-term stress from incompatible LED loads.

What wears out inside: Component failure (e.g., triac, MCU, power supply components) due to electrical stress, thermal fatigue, or corrosion from moisture. This can lead to loss of control logic or dimming capability.

Symptom on machine: Complete loss of light function, erratic sensor behavior, inability to dim, or continuous-on state. Requires full fixture replacement.

Cross-Compatible Platforms: BesLowe brand family design patterns (open-bottom E26 socket, dimmable LED/incandescent recommendation, PIR + photocell 3-mode architecture) are consistent with sibling models, but specific features like adjustable standby brightness differ for this SKU.

Other BesLowe 1046AR Problems (3)
1. Quick Test 2. See Fix Parts ↓

Type any brand, model number, error code, or part number...