Holding the On/Off button (Pos B) for 10 seconds or deleting from the app fails to produce the expected flash confirmation.
02 // Non-Invasive Meter / Bench Verification
Verify the fixture is receiving continuous 120V AC power (0.5s startup), hold Pos B firmly for a full 10 seconds until the LED array flashes, or delete the device tile inside the Cync App while connected to Wi-Fi/BLE.
Platform / OEM Cross-Reference: All three bar lengths (CFIXUNCBR12CRVDMS, CFIXUNCBR18CRVDMS, CFIXUNCBR24CRVDMS) and the 3-inch puck (CFIXUNCPK03CRVDMS) share the exact same FCC ID: PUU-CFIXCNLRCRV wireless module, 2-button UI (Pos B, C), 10-unit linking limit, and 5-year warranty operating conditions, differing only in optical waveguiding (edge-lit bars vs. back-lit pucks) and wattage/lumen scaling.
Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN
Role
OEM MPN / Spec
Component & Fitment Notes
Est. Street
Check Stock
Part 1 accessory Isolated Match
Cync CWLSWDMBWF1
Optional Wire-Free Smart Dimmer Switch Official accessory for wireless control and dimming without requiring a wired wall dimmer.
Material / Sensor Nodes:CopperLithium IonLithium-Ion
Failure Physics & Causal Isolation
Safety & Disassembly Lockouts:
NOTE: Once the knock-out is removed, the Undercabinet Bar can only be hardwired and can no longer be plugged in.
Before Ordering Parts: Normal Operation vs. True Fault
False-Alarm Check — User toggles 'Reveal' button in Cync App and observes a noticeable drop in overall white brightness (-16% to -21.7% lumen reduction).: Official specs confirm reveal® HD+ mode outputs lower lumens (e.g., 630 lm vs 750 lm std on 12-in) because yellow/green wavelengths are suppressed to enhance red/white contrast. This is an intentional spectral filtering effect. (True fault when: Only a fault if output drops >50% or flickers erratically.)
False-Alarm Check — Multiple bars are physically chained with linking cables (Pos F), but pressing the physical On/Off (Pos B) or Color (Pos C) button on Bar #1 does not change Bar #2 or Bar #3.: The physical linking cable carries 120V AC power only (zero data lines). Per official Cync Support, physical buttons only control individual bars unless the fixtures are assigned to the same Room/Group inside the Cync App. Pairing via Matter to Apple Home removes Cync App group binding, causing physical buttons to operate individually. (True fault when: If bars are grouped in the Cync App and still do not sync, or if the button fails to control its own bar.)