INDARUN D3142WIFI-INUS: Zero illumination across all deck pucks
What this means: All connected deck lights are completely off.
60-Second Verification Check
Check GFCI Reset button; verify 120V AC at outlet; measure 12V DC at power adapter output. If 12V is present at adapter but 0V after controller, controller has failed.
Verified Replacement Parts
DC 12V LED Power Supply / Transformer
Available on FVTLED platform and generic electronics distributors. Match wattage and connector type.
Inline IP67 Wi-Fi RGB Smart Controller
Available on FVTLED platform, which shares architecture with INDARUN.
Why This Happens & Safety Warnings
What triggers it: Outdoor exposure without weatherproof cover or running near 100% load
What wears out inside: Internal capacitor dry-out, component overheating, or GFCI ground-fault trip
Symptom on machine: Total system blackout (no lights)
Cross-Compatible Platforms: INDARUN D31 Wi-Fi RGB kits share app (FVTLED/Surplife), troubleshooting (5× power-cycle reset, WPA2 requirement), and modular hardware accessories with FVTLED.