Root Failure Mechanism: Li-ion Battery Capacity FadeClick to spotlight part ↑
01 // Trigger ConditionRepeated use and charging cycles over time, or prolonged storage at 0% charge, or exposure to high ambient temperatures.
02 // Degradation PhysicsElectrochemical aging of lithium-ion cell, leading to irreversible loss of active material and increased internal resistance.
03 // Lockout / ImpactSignificantly reduced runtime per charge, requiring more frequent recharging; eventual inability to hold a useful charge.
Before Ordering Parts: Normal Operation vs. True Fault
False-Alarm Check — Light dims or shuts off after fewer hours than expected.: The 2000mAh Li-ion battery has a finite capacity, and runtime is directly affected by brightness level. At 100% brightness, the battery depletes faster. Additionally, the remote receiver has a constant, albeit small, parasitic drain. (True fault when: If runtime significantly decreases after only a few charge cycles, or if the light fails to hold any charge.)
False-Alarm Check — Remote control does not work.: New remotes often have a plastic battery pull-tab that must be removed. Remote controls require line-of-sight (IR) or can have limited range (RF). The coin cell battery in the remote will eventually deplete. (True fault when: If the remote has a fresh battery, pull-tab removed, clear line-of-sight, and still fails to operate, while the on-unit touch control functions correctly.)