Lights stay continuously ON even in daytime/AUTO mode; replacing photo eye does not fix.
02 // Non-Invasive Meter / Bench Verification
Unplug unit from 120V outlet and leave dial in ON position long enough to fully drain the internal timer-keeper backup battery, then plug back in to hard-reboot logic.
Platform / OEM Cross-Reference: Shares the 3150-9045-92 detachable photo sensor and digital timer HMI architecture with Malibu 8100-9045-01 (45W) and 8100-0200-01 (200W) power packs.
Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN
Role
OEM MPN / Spec
Component & Fitment Notes
Est. Street
Check Stock
Part 1 oem replacement part Isolated Match
Independent Technician &…
Internal Memory Backup Battery Requires matching voltage and chemistry to existing PCB-mounted cell.
Material / Sensor Nodes:ABSBRASSCopperPolypropyleneTRIAC
Failure Physics & Causal Isolation
Safety & Disassembly Lockouts:
Unauthorized internal repairs or modifications void the 1-year warranty.
Never submerge unit.
Root Failure Mechanism: Digital Control Logic Lockup ('Failed-On' State)Click to spotlight part ↑
01 // Trigger ConditionExposure to power-line transients or brownouts.
02 // Degradation PhysicsPower fluctuations corrupt the microcontroller's state; the backup battery maintains this corrupted state, preventing a full reset.
03 // Lockout / ImpactLights stay stuck ON continuously, regardless of mode dial or photo eye input.
Before Ordering Parts: Normal Operation vs. True Fault
False-Alarm Check — Steady, low-level 60 Hz / 120 Hz buzzing/humming sound while energized.: Slight steady hum under load is explicitly documented as normal magnetostrictive behavior of the laminated magnetic transformer core. (True fault when: Loud rattling buzz or hot housing indicates overload (>120W), loose terminal connections, or core delamination.)
False-Alarm Check — 15-second pause between darkness/covering sensor and lights illuminating.: A 15-second anti-nuisance delay in AUTO and 4/6/8/10 modes prevents false triggers from transient light changes (e.g., lightning, car headlights). (True fault when: If the delay is significantly longer, or the sensor does not respond at all after the delay, it may indicate a fault. Switch dial to TEST mode (0-second delay) to verify sensor immediately.)