01 // Observed Condition

The physical button on the switch does not latch the relay state, only momentarily activating the load while pressed. This occurs specifically after flashing with an incorrect or outdated Tasmota template for a revised hardware version.

02 // Non-Invasive Meter / Bench Verification

Verify the Tasmota template version against the hardware revision (ESP8266 vs. BK7231N) and apply the updated Blakadder 'KULED-B' template with auxiliary relay mapping.

Platform / OEM Cross-Reference: Shares hardware chassis and ETL lineage with KULED KS-602S and Micmi K36 1-pack/2-pack/4-pack bundles.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
Any UL/ETL-Listed 15A… Complete Replacement Switch Module
Must match electrical ratings (15A/1800W, 120V AC), neutral wire requirement, and physical form factor (Decora, 1-gang). ETL/UL listing ensures safety compliance.
OEM: ~$12.50/ea (4-pack $49.99) / Marketplace: ~$15–$48
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified smart automated lighting replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:BRASSCopperMosfetTRIAC

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Opening the 4-screw housing to flash third-party firmware voids manufacturer warranty coverage.
  • To preserve Intertek ETL safety certification and UL94 V-0 fire containment, the switch is designed as a modular field-replaceable assembly rather than a user-repaired internal PCB.

Root Failure Mechanism: Catalog Misapplication (Dimming Expected)Click to spotlight part ↑

01 // Trigger ConditionBuyer purchases K36 based on marketplace listing title advertising 'Smart Dimmer Light Switch'.
02 // Degradation PhysicsMismatch between advertised functionality and actual hardware capability (ON/OFF relay switch vs. dimmer).
03 // Lockout / ImpactUser frustration, perceived product defect, inability to dim lights, product return.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Audible Mechanical Click: The crisp 'click' sound is a normal physical characteristic of an electromechanical relay engaging or disengaging to switch the 120V AC load. It indicates the relay is functioning as designed. (True fault when: An unusually loud, grinding, or repetitive clicking (chatter) without a corresponding load change could indicate a fault in the relay, power supply, or control circuit.)

Other Micmi K36 Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...