Model EXS-S-0200: Partial Strand Outage
What this means: A block of LEDs (e.g., 25–50 LEDs) goes dark.
60-Second Verification Check
Inspect dark section for pinched/kinked wire or moisture intrusion at an LED base.
Verified Replacement Parts
Outdoor Mounting Clips
Prevents wire jacket damage compared to metal staples, supporting proper installation.
Why This Happens & Safety Warnings
What triggers it: Repeated coiling/uncoiling, pulling, or wind abrasion during installation/storage/use.
What wears out inside: Conductor fatigue, work-hardening, or broken solder joints at LED legs.
Symptom on machine: Loss of illumination in a section of the string light.
What triggers it: Prolonged outdoor exposure to freeze-thaw cycles, UV radiation, and moisture.
What wears out inside: Degradation of epoxy seal (e.g., micro-cracks, hazing) allowing capillary moisture ingress along wire leads, leading to corrosion of LED lead frames or internal components.
Symptom on machine: Failure of individual LEDs or small banks of LEDs.