SMY Lighting SMY-DK-20: Lights Rapidly Cycle On and Off at Night
What this means: Continuous blinking/strobing every few seconds.
60-Second Verification Check
Normal feedback physics if photocell faces one of the deck lights or a porch light; shield/reposition sensor. If cycling persists in total darkness, check for wet shorted 2-pin connector triggering SMPS hiccup mode.
Verified Replacement Parts
Inline Photocell / Timer / Dimmer Module
Connector pinout must match.
Waterproof 2-Pin Extension Cable
Verify connector pin pitch.
Silicone Dielectric Grease
Applied sparingly to 2-pin connectors during assembly to prevent moisture-induced verdigris corrosion.
Why This Happens & Safety Warnings
What triggers it: Outdoor exposure, loose connections, or missing end cap.
What wears out inside: Under-tightened collars, missing O-rings, or uncapped terminal ends let rain bridge energized 12V DC pins, rapidly corroding brass contacts.
Symptom on machine: Flickering lights, downstream blackout, or dimming of distal lights.
What triggers it: Outdoor exposure, moisture ingress, or sensor degradation.
What wears out inside: Moisture ingress into the inline control housing or CdS sensor drift causes lights to stay on continuously, fail to trigger at dusk, or lose timer memory.
Symptom on machine: Incorrect light operation (on/off at wrong times, loss of dimming/timer).
Cross-Compatible Platforms: 12V DC parallel 2-pin twist-lock architecture