Error Code Model: BR1500MS2

APC BR1500MS2: F02 (On-Battery Output Short)

What this means: Detected short circuit on battery-backed outlets, leading to shutdown. May be accompanied by burnt odor reports.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Audible mechanical clicking during voltage sags/swells; fan ramp up to 45 dBA on battery operation. — Clicking indicates the AVR autotransformer's tap relays engaging to boost or trim voltage, which is normal operation. The fan activates to cool the inverter and transformer, especially under load or on battery, and 45 dBA is within the published acoustic specification.

Unplug all loads and reseat battery plug. If F02 persists unloaded, internal inverter short is confirmed — contact SEIT support.

2

Verified Replacement Parts

#1 Most Likely Fix OEM: ~$110–$140 USD (est.) / Pre-assembled 3P: ~$85–$95 USD

Complete Replacement Battery Cartridge

APCRBC163 Copy Part #

Plug-and-play drop-in replacement, designed to match OEM specifications.

Option #2 • Budget Aftermarket ~$45–$65 USD (pair of bare cells)

Bare Matched VRLA Battery Cells (2-Pack)

2x 12 V 9 Ah (or 9.4 Ah… Copy Part #

Requires careful transfer of existing OEM fuse harness and spacers from the APCRBC163 cartridge. Cells must be matched.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in line interactive pure sine wave ups replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • APC official documentation classifies F03, F04, F05, F06, F07, F08, and F09 as non-user-serviceable internal hardware faults requiring RMA/replacement rather than field repair. High-voltage DC bus capacitors and mains-referenced traces present shock hazards if serviced without isolation training.
On-Battery Overload / Output Short (F01 / F02)

What triggers it: Connected load on battery-backed outlets exceeds 900 W (F01) or a downstream device creates a short circuit (F02).

What wears out inside: Inverter overload protection engages, or internal inverter MOSFETs may short if protection fails.

Symptom on machine: UPS alarm, shutdown, loss of power to connected devices. Persistent F02 may indicate internal hardware damage requiring RMA.

Cross-Compatible Platforms: F01–F09 fault code matrix and PowerChute Serial Shutdown ecosystem shared across the APC Back-UPS Pro (BR/BN/BX) tower family.

Other APC BR1500MS2 Problems (6)
1. Quick Test 2. See Fix Parts ↓

Type any brand, model number, error code, or part number...