FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: TC147 TIER 1–2 BENCH DIY

BINTA TC147: Current Direction Inverted

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Display shows discharge (-) while charging or charge (+) while discharging.

02 // Non-Invasive Meter / Bench Verification

Confirm B- connects exclusively to battery negative and P- connects to all load/charger negatives.

Platform / OEM Cross-Reference: Sibling BINTA monitors include TR16H (0-150A) and VA9910 (500A).

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
50A Current Shunt 50A Current Shunt
The shunt is calibrated to the TC147 sampler PCB; substitution with an uncalibrated generic shunt without matching mV/A ratio is not recommended for accuracy.
Sold as complete kit
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified compact shunt based battery coulombmeter voltmeter ammeter replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSBRASSCopperEepromLifepo4Lithium-Ion

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Manual prohibits abrasive cleaners and chemical solvents for display cleaning.

Root Failure Mechanism: Inverted Current PolarityClick to spotlight part ↑

01 // Trigger ConditionIncorrect wiring during installation.
02 // Degradation PhysicsReversing the B- and P- leads on the shunt causes the current measurement polarity to invert.
03 // Lockout / ImpactDisplay shows charge (+) during discharge and discharge (-) during charge, leading to incorrect SoC calculation and confusion.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check β€” Screen Goes Dark During Idle: This is a normal power-saving behavior due to the auto-sleep feature. (True fault when: If the display does not wake up by pressing any button, or if it remains dark even when the battery is within the operating voltage range and cables are secure.)

Other BINTA TC147 Diagnostic Sheets