ChargePoint Home Flex CPH50-NEMA14-50-L23: Solid or blinking red LED
What this means: Charging halted, indicating CCID, relay, or ground fault.
60-Second Verification Check
Unplug EV, cycle breaker OFF for 2 minutes, and inspect upstream ground continuity and L1/L2 voltage (208–240V AC). Persistent red LED with verified power indicates internal relay/CCID hardware fault.
Verified Replacement Parts
23 ft Replacement J1772 Cable Kit
Official OEM kit ensures UL listing and proper internal clamp/gland termination.
23 ft NACS Conversion Cable Kit
Official OEM upgrade kit to convert J1772 CPH50 to native NACS (SAE J3400) while maintaining UL listing.
Why This Happens & Safety Warnings
- To preserve UL 2594/2231 personal shock protection, calibrated 20 mA CCID detection, and NEMA 3R weatherproofing, the internal control PCB, Wi-Fi module, and main power relays are housed behind a sealed internal barrier. ChargePoint does not sell board-level replacement parts; internal electronics or Wi-Fi hardware failures are resolved via full main-body warranty replacement.
What triggers it: Voltage sags, surges, high cycle count, or abrupt unplugging under load.
What wears out inside: Contact arcing degrades relay contacts (leading to welding) or triggers a permanent CCID20 ground-fault lockout.
Symptom on machine: EVSE halts charging, displays a red fault LED, and becomes inoperable.
Cross-Compatible Platforms: CPH50 chassis, NEMA 3R rating, -30°C to 50°C operating range, CCID20 protection, 3-year warranty, and ChargePoint app ecosystem are shared across the NEMA 14-50, NEMA 6-50, Hardwired, and NACS CPH50 variants.