Dyness AR2.5-24V: Localized Terminal Heating
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Warm/hot cable lug or softening polymer around terminal post.
02 // Non-Invasive Meter / Bench Verification
De-energize immediately; inspect for oxidized lugs, undersized wire gauge, or misplaced washers between lug and terminal base.
Platform / OEM Cross-Reference: Dyness (Daqin New Energy Tech) is an established LiFePO4 ESS manufacturer; however, do not transfer 48V rack-mount ESS specs (CAN/RS485, breaker switches, 6,000-cycle rack ratings) onto the drop-in AR2.5-24V SKU without explicit datasheet verification.