ECO-WORTHY Cubix100: Charge stops around 54.8V–55.6V with Cell Over-Voltage alarm
What this means: One or more cells in the 16S stack reach over-voltage protection (3.65V) prematurely due to imbalance.
60-Second Verification Check
Check per-cell voltages via Bluetooth/PC app. Hold at 55.2V–56.0V at low current (5A–10A) until cell delta drops below 30–50 mV.
Verified Replacement Parts
16S 100A Smart LiFePO4 BMS
Exact harness pinout, communication protocols, and physical dimensions must match for compatibility.
Why This Happens & Safety Warnings
- Factory tamper seals and internal dielectric barriers are engineered to prevent accidental 51.2V high-fault-current shorts (capable of greater than 1,000A arc flash); unauthorized internal opening during the warranty window can affect RMA eligibility.
What triggers it: Chronic partial-SOC cycling without regular full top-charge cycles.
What wears out inside: Passive balancing cannot converge cell voltage deltas; highest cell triggers 3.65V OVP prematurely.
Symptom on machine: Reduced usable capacity; charge cycle terminates early.
Cross-Compatible Platforms: Shares the ECO-WORTHY 48V (51.2V) 100Ah 3U server-rack LiFePO4 platform (16S prismatic stack, 100A BMS, 125A front breaker, parallel-only scalability up to 15 units, CAN/RS485/RS232 ports). Exact Cubix100 deltas (LCD, dual terminals, Wi-Fi/BT, UL cert) require live spec verification.