EMPORIA Pro Level EMC2V3-A: 3 slow / 1 fast
What this means: False Ventilation Request Error; refuses to charge.
60-Second Verification Check
Cycle breaker to rule out glitch; modern lithium-ion EVs do not request ventilation—persistent 3s/1f indicates EVSE fault requiring Support RMA.
Verified Replacement Parts
Complete EVSE Unit (White, Hardwire, J1772)
UL-listed sealed assembly, must be OEM for warranty and safety.
Why This Happens & Safety Warnings
- Do not open or attempt to repair internal components; preserve factory NEMA 4 seal and contact Emporia Support with serial number for diagnostics/RMA.
What triggers it: Internal EVSE Control Pilot (CP) sensing circuit malfunction.
What wears out inside: CP voltage/resistance is misread, causing the EVSE to incorrectly interpret a 'State D' (ventilation required) signal from the vehicle.
Symptom on machine: Immediate charge abort, preventing the EV from charging.
Cross-Compatible Platforms: Orange slow/fast LED fault code table (1s/2f through 3s/2f), FCC radio 2AS6P-EMEVSE1, and cold-weather cable flexibility characteristics are shared across the Emporia Classic and Emporia Pro EVSE hardware platform.