HCDC HD060: Unit powers load initially, then shuts off output after running; resumes working for a few minutes if unplugged to cool for 30 minutes
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Internal relay coil overheated inside the sealed plastic case, opening the coil circuit until cooled.
02 // Non-Invasive Meter / Bench Verification
Confirm by measuring voltage at AC INPUT 2 (120V present) vs. AC OUTPUT (0V) when AC INPUT 1 is disconnected.
Platform / OEM Cross-Reference: Connector Variant Sibling Mapping: Link HCDC HD060B (NEMA 5-15P/R pre-wired) and HCDC HD060C (IEC320 C14/C13) as direct connector variants of the HD060, and map OONO F-1051 / F-1051B / F-1051C as shared-platform CZH-LABS / Xiken-Tech equivalents.