FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: LB230-S TIER 1–2 BENCH DIY

Leviton LB230-S: Solid/blinking amber or red connectivity LED; breaker shows 'Offline' in My Leviton app

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Indicates a loss of communication between the smart breaker and the Leviton hub (LWHEM/LDATA) or the My Leviton cloud.

02 // Non-Invasive Meter / Bench Verification

Verify LWHEM/LDATA online status and Wi-Fi signal strength outside steel panel door. Check for firmware updates.

Platform / OEM Cross-Reference: All plug-on Leviton Load Center bus interface, hydraulic-magnetic trip curve stability, white rocker handle, and My Leviton app ecosystem apply across the Leviton LBxxx-S smart breaker family.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
LB230-S Complete Replacement Smart Breaker
Proprietary UL-listed Leviton Load Center interface; no generic cross-reference permitted.
~$115–$135 OEM
Part 2
accessory
Isolated Match
LWHEM-2R Whole Home Energy Monitor (2nd Gen Hub)
Proprietary My Leviton ecosystem.
~$200–$250 OEM
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified residential smart branch circuit breakers replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:CopperSilicone

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • To maintain UL 489 dielectric integrity, calibrated hydraulic-magnetic trip accuracy, and tamper-resistant safety compliance, the breaker housing is permanently factory-sealed. Opening the housing voids UL listing and manufacturer warranty; internal components (PCB, contacts, hydraulic cylinder) are strictly non-serviceable and require full unit replacement.

Root Failure Mechanism: Wireless Telemetry Drop / Offline StateClick to spotlight part ↑

01 // Trigger ConditionBreaker installed in steel load center or far from Wi-Fi router/hub.
02 // Degradation PhysicsRF signal attenuation by steel enclosure, Wi-Fi channel interference, or hub synchronization loss.
03 // Lockout / ImpactBreaker appears 'Offline' in My Leviton app, preventing remote control and energy monitoring. Mechanical overcurrent protection remains active.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Distinct single electromechanical snap when toggled via app: This is normal behavior during remote switching, indicating the internal solenoid/motor mechanism is operating as designed. (True fault when: Abnormal if rapid chattering or repeated uncommanded clicking occurs.)
False-Alarm Check — Mild exterior case warmth during continuous 80% load: Circuit breakers dissipate heat under load, especially when operating near their continuous current rating (24A for this 30A breaker). This warmth is within UL rise limits. (True fault when: Abnormal if hot to touch, smelling of ozone/plastic, or showing discolored insulation on the breaker or panel components.)

Other Leviton LB230-S Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...