FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: FS-311 TIER 4 LICENSED / SEALED

Mini FS-311: Unit Will Not Charge / No LEDs

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Dead unit on AC mains, no status LEDs illuminated.

02 // Non-Invasive Meter / Bench Verification

Test AC outlet and swap figure-8 cord. If still dead, internal SMPS primary stage or BMS has faulted.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
routine consumable
Isolated Match
IEC 60320 C7 (Figure-8)… AC Power Cord
Standardized connector type; must match C7 socket on unit.
Generic: $5–$10
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified dc mini ups backup replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSBRASSLifepo4Lithium-IonMosfetNTC

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Opening the housing exposes live AC mains voltage and voids retailer warranty coverage.

Root Failure Mechanism: SMPS Electrolytic Capacitor DryingClick to spotlight part ↑

01 // Trigger ConditionContinuous 24/7 operation plugged into AC mains.
02 // Degradation PhysicsElectrolyte drying out due to continuous thermal stress, leading to increased Equivalent Series Resistance (ESR) and reduced capacitance.
03 // Lockout / ImpactOutput voltage ripple, instability of connected devices, or complete failure (dead unit).

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Mildly warm enclosure surface during operation or charging.: The unit is passively cooled and generates heat from the internal AC-DC SMPS and battery charging process, especially when recharging from a low state. Surface temperatures up to 45°C are normal. (True fault when: If the enclosure is too hot to touch (greater than 55°C), emits a burning odor, or causes connected devices to malfunction.)

Other Mini FS-311 Diagnostic Sheets