Smart See OEM Spec: Severe Enclosure Heating (>= 55.0 degC) at Zero Electrical Load
What this means: Housing and internal PCB reach 55 degC+ with 0A load when custom firmware (ESPHome/OpenBeken) holds H-bridge GPIO P24 or P26 continuously high instead of issuing a momentary millisecond latching pulse.
60-Second Verification Check
Immediately de-energize the circuit via the upstream MCB if the housing is hot at zero load after firmware modification; verify GPIO pulse-drive configuration before re-energizing.
Verified Replacement Parts
60A 250V Bistable Magnetic Latching Relay & SOT23-6 H-Bridge Driver
Relay is spot-welded/brazed to the 1 mOhm manganin shunt and M4 cages with no public datasheet; transplanting compromises high-current safety and calibration—treat as non-serviceable (replace complete DIN switch).
Why This Happens & Safety Warnings
- Installation, wiring, and inspection inside the distribution panel must be performed by a qualified electrician with upstream mains power completely disconnected.
- Always pair downstream of an appropriate thermal-magnetic circuit breaker (MCB) and Surge Protective Device (SPD); TO-Q-SY1 models provide zero overcurrent or short-circuit protection.
What triggers it: User drills housing rivets to flash OpenBeken or ESPHome onto BK7231N and configures GPIO P24 or P26 as a standard continuous relay output instead of a momentary H-bridge pulse.
What wears out inside: Continuous DC current flows through the SOT23-6 H-bridge and momentary-duty bistable relay coil, generating severe steady-state heat (55 degC+ with zero load) that degrades coil enamel and driver silicon.
Symptom on machine: Burned-out relay coil or SOT23-6 H-bridge driver IC, enclosure overheating, and voided warranty.
Cross-Compatible Platforms: TONGOU (TO-Q-SY1-JWT, TO-Q-SY2-JWT, TO-Q-SYS-JWT) and TOMZN (TOMPD-63SW, TOVA-63T, TOB9S-VAP, TOB9L-63WIFI) represent the underlying ODM platforms for generic 'Smart' / 'Tuya' Wi-Fi DIN-rail energy meter switches.