BLACK+DECKER CM5000B: No Heat / Cold Water Only (LCD Lit)
What this means: Display works normally, but water never pumps or warms.
60-Second Verification Check
Technician continuity check across heater element and series TCO.
Verified Replacement Parts
Thermal Cutoff Fuse (TCO)
Critical safety component. Replacement requires matching the exact temperature rating of the original part. Installation must be crimp-only (never solder) using high-temp uninsulated crimp ferrules.
Why This Happens & Safety Warnings
- Never immerse the base unit, cord, or plug in water.
- Do not attempt to service internal components during the warranty period; contact authorized customer support.
What triggers it: Severe scale insulation of the heater tube or a stuck/failed bimetallic thermostat.
What wears out inside: The heater block exceeds the TCO's trip threshold, causing the one-shot fuse to permanently open the circuit as a safety measure.
Symptom on machine: The heating element receives no power, resulting in cold water and no brewing.
Cross-Compatible Platforms: 2-year limited residential household warranty administered by Empower Brands (BLACK+DECKER appliance licensee).