De Jong DUKE Virtu: Waste Bucket Full / Empty Waste Bucket

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Preventive lockout alert triggered by the MoVeC firmware cycle-count algorithm (or waste switch) indicating the solid puck waste bin or drip tray requires emptying.

02 // Non-Invasive Meter / Bench Verification

Physically empty, rinse with warm water, and reinstall the waste bucket and drip tray. If the message persists because it is governed by a firmware cycle counter rather than a physical weight sensor, clear it manually via Touchscreen -> Service Menu -> Login 4444 -> Reset Waste Basket.

Platform / OEM Cross-Reference: MoVeC ICEQ control architecture, CoEx brewer assemblies, and PPSU hydraulic manifolds are shared across the De Jong DUKE Virtu, Zia, Nio, Varea, and Lua platforms.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
9EPR018 MoVeC ICEQ2 Main Logic Controller PCB
Proprietary multi-layer PCB with onboard USB flash interface. Must match Pre-2021 (ICEQ) vs Post-20210824 (ICEQ2) revision compatibility and must be flashed with firmware matching the exact Virtu chassis configuration.
$550 - $600 OEM
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified commercial super automatic bean to cup coffee machine replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:BRASSEPDMNTCSiliconeStainless SteelTRIAC

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Opening the front door disables dispensing via a safety interlock switch; initiating automated maintenance with the door open requires inserting the dedicated physical green Service Key.
  • Servicing the PPSU pressure boiler (Pos 6503), heating elements (1.3 kW / 2.9 kW), or pressure relief valves (4MPF084) requires isolating 120V/230V mains power and bleeding residual 1.1 MPa (11 bar) water / 0.5 MPa (5 bar) steam pressure to prevent severe scalding and electrical shock.

Root Failure Mechanism: Persistent 'Waste Bucket Full' Lockout Due to Unreset Firmware Cycle CounterClick to spotlight part ↑

01 // Trigger ConditionOperator physically empties the solid waste bucket after a 'Waste Bucket Full' prompt without resetting the software counter in the Service Menu.
02 // Degradation PhysicsBecause many Virtu configurations track waste capacity via a mathematical cycle-count algorithm in the MoVeC controller rather than a physical weight sensor, the firmware counter remains at its limit.
03 // Lockout / ImpactMachine continues displaying 'Waste Bucket Full / Empty Waste Bucket' and blocks dispensing despite an empty bin until reset via PIN 4444.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Touchscreen displays 'Wait, Heating Boiler' and temporarily pauses beverage dispensing for 10 to 20 minutes.: Standard thermodynamic recovery period required for the 1.3 kW (120V North America) or 2.9 kW (230V EU/Global) immersion heating element to bring cold mains water in the PPSU pressure boiler back to target temperature after cold startup, deep cleaning, or heavy back-to-back dispensing. (True fault when: Indicates a hardware fault only when the 'Wait, Heating Boiler' screen persists continuously for more than 20 minutes, pointing to a blown thermal limit fuse, heavy CaCO3 scale insulating the element, or a failed 6CSS037 NTC temperature/pressure sensor.)
False-Alarm Check — Noticeably lower hydraulic extraction pressure and faster flow rate when brewing standard Filter/Coffee recipes (1-8 bar) compared to Espresso recipes (9-12 bar).: The patented CoEx brewer dynamically modulates its physical chamber geometry via the cam linkage and flow restriction algorithm to deliver 1-8 bar for standard coffee and 9-12 bar for espresso. (True fault when: Indicates a fault only if espresso recipes fail to build 9-12 bar pressure or if pressurized slurry visibly bypasses a worn 4ROR014 filterhead quad-ring into the drip tray.)