De Jong DUKE Virtu: Waste Bucket Full / Empty Waste Bucket
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Preventive lockout alert triggered by the MoVeC firmware cycle-count algorithm (or waste switch) indicating the solid puck waste bin or drip tray requires emptying.
02 // Non-Invasive Meter / Bench Verification
Physically empty, rinse with warm water, and reinstall the waste bucket and drip tray. If the message persists because it is governed by a firmware cycle counter rather than a physical weight sensor, clear it manually via Touchscreen -> Service Menu -> Login 4444 -> Reset Waste Basket.
Platform / OEM Cross-Reference: MoVeC ICEQ control architecture, CoEx brewer assemblies, and PPSU hydraulic manifolds are shared across the De Jong DUKE Virtu, Zia, Nio, Varea, and Lua platforms.