01 // Observed Condition

Cooling takes over 4 minutes; smoke backs up at roaster front.

02 // Non-Invasive Meter / Bench Verification

Remove and hold mesh screen up to light; if over 30% of pores are occluded by oil/chaff, deep degrease and verify damper travel.

Platform / OEM Cross-Reference: Designed to pair with KALDI Mini / Wide / Wide400 / Fortis drum roaster exhaust ports; manual rotary fan speed control and dual-mode damper topology.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
304 Stainless Woven Wire… Stainless Chaff Filter Mesh / Basket
Must match original dimensions and mesh size for effective filtration and fit.
Check Live Stock
Part 2
universal aftermarket part
Isolated Match
Semi-rigid aluminum or… Flexible Exhaust Duct & Clamps
Must match collar diameter and be rated for high temperatures. Avoid plastic/vinyl dryer ducting (fire hazard).
Generic: $10–$25
Part 3
routine consumable
Isolated Match
Sodium percarbonate … Food-Safe Coffee Oil Degreaser
Safe on stainless steel mesh and cooling trays; keep off bare aluminum ducting.
$10–$25
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified cyclone chaff collectors and bean coolers replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMFAULT IMPLICATED
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSCopperSiliconeStainless SteelTRIAC

Failure Physics & Causal Isolation

Root Failure Mechanism: Chaff Mesh Screen & Duct Airflow ChokingClick to spotlight part ↑

01 // Trigger ConditionRegular coffee roasting operation
02 // Degradation PhysicsVaporized coffee oils condense on screen and duct walls, trapping fine chaff and forming creosote.
03 // Lockout / ImpactStatic pressure drops, leading to slow bean cooling, smoke backing up at the roaster, and reduced chaff collection efficiency.

Root Failure Mechanism: Damper Binding from Coffee TarClick to spotlight part ↑

01 // Trigger ConditionExposure to coffee roast smoke condensate
02 // Degradation PhysicsSmoke condensate polymerizes on the sliding track of the damper, forming sticky tar.
03 // Lockout / ImpactDamper jams mid-travel, preventing proper redirection of suction between cooling tray and roaster exhaust, leading to inefficient cooling or smoke backup.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Audible 50/60Hz electrical buzz; rotor stalled at low knob position.: This is normal physics for phase-angle dimmed AC fans if the speed controller is set too low, below the motor's minimum breakaway voltage. (True fault when: If the fan stalls at mid-speed settings, or if it fails to start even at high settings, it may indicate thickened bearing grease, a failing capacitor, or a faulty speed controller.)