FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: G3 TIER 1–2 BENCH DIY

Tuni G3: Uneven Espresso / Muddy Pour-Over

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

High fines content, channeling, or slow pour-over drawdown.

02 // Non-Invasive Meter / Bench Verification

Perform dry-erase marker burr alignment test and foil-shim upper burr carrier.

Platform / OEM Cross-Reference: Shardor 64mm / Mokkom 64mm technical findings (brass threads, magnetic chute, bottom cooling fan, 0.2g retention with RDT+bellows, SSP fitment, alignment shimming) apply to the Tuni G3, noting that Tuni upgrades the outer shell to stainless steel (7.3 lbs vs. 6.0 lbs).

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
Standard 64mm flat burrs… 64mm Replacement Flat Burrs
Physical fitment confirmed on shared platform; alignment shimming may be required.
~$30–$45 USD (generic SS) / ~$185–$200 USD (SSP)
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified single dose flat burr grinders replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORNOMINAL ON SKU
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMFAULT IMPLICATED
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSBLDCBRASSSiliconeStainless SteelTRIAC

Failure Physics & Causal Isolation

Root Failure Mechanism: Burr Misalignment / Drive Shaft RunoutClick to spotlight part ↑

01 // Trigger ConditionInitial setup or after burr cleaning/replacement
02 // Degradation PhysicsBudget machining tolerances leading to non-parallel burr planes or slight central drive shaft wobble.
03 // Lockout / ImpactBimodal fines distribution in grounds, leading to uneven espresso extraction (channeling, sour/bitter shots) or muddy pour-over.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Flashing Power Button in Standby: This is a documented normal standby behavior for the embedded MCU sleep state. (True fault when: If the unit does not respond to a tap on the power button to wake up, or if other symptoms (e.g., no motor spin) are present.)

Other Tuni G3 Diagnostic Sheets