1byone 6-O00QH-0499: Receiver melody and volume reset to default Chime #1 after power interruption
What this means: Loss of user-selected melody index following AC utility grid outages, brownouts, or unplugging the receiver from the wall outlet.
60-Second Verification Check
Press the receiver melody selector button sequentially to cycle through the 36 tones and restore the desired chime setting.
Verified Replacement Parts
1byone Add-On / Replacement Plug-In AC Chime Receiver
Exact factory AC receiver hardware model specified in O00QH-0499 engineering sheets; unlimited receivers can pair to a single transmitter.
Why This Happens & Safety Warnings
- Do not mix old and new batteries, or mix alkaline, standard (carbon-zinc), or rechargeable (ni-cad) batteries.
- Do not install the indoor chime receiver outdoors or expose it to rain or moisture.
What triggers it: Brief utility grid power outage, electrical storm dropout, or unplugging the QH-831A receiver from the wall receptacle.
What wears out inside: Loss of AC mains power drops the internal DC rail (no backup battery); on hardware revisions lacking non-volatile EEPROM for melody index storage, the microcontroller reverts to default Melody #1 and default volume upon power restoration.
Symptom on machine: Owner annoyance requiring manual cycling through up to 36 melodies via the side push button to restore the preferred chime tone.
Cross-Compatible Platforms: IP56 ingress protection is certified on parallel 1byone platforms sharing the identical sensor chassis mold, whereas exact-SKU retail documentation labels the sensor 'weatherproof'.