aosu C9C3CA11: Motion Detection Latency / Clipped Event Recordings
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Recorded motion clips begin only after a fast-moving person or vehicle has already passed through most of the frame, or auto-tracking lags behind the subject.
02 // Non-Invasive Meter / Bench Verification
Verify camera mounting height is within 2.0 to 3.0 m above grade, clean the front Fresnel PIR window with a damp microfiber cloth, and aim the static ~83° horizontal lens FOV toward the approach path rather than perpendicular to fast cross-traffic.
Platform / OEM Cross-Reference: Expandable local storage up to 1 TB applies strictly to 2nd-Gen aosuBase hubs bundled with 5MP (3K) 6-cam kits, and 16 TB expansion applies only to aosuCortex 8-cam kits; neither applies to B0CNRDG796.