BILLCONCH B2: Keypad white LEDs illuminating repeatedly without physical contact, followed by dead battery within 48 hours
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Owner-reported symptom where the membrane switch matrix wakes continuously in a loop, exhausting the 18650 cell.
02 // Non-Invasive Meter / Bench Verification
Wipe the keypad fascia with a dry microfiber cloth to rule out surface contamination; unlock with the backup key or external 5V Micro-USB supply and inspect battery voltage.
Platform / OEM Cross-Reference: Sister model A2 shares the identical cold-rolled carbon steel chassis, rear torsion-spring hinge architecture, 18650 battery holder, and motorized rotary cam latch assembly, but omits the Bluetooth BLE module and uses a simplified 5-digit keypad.