D1D9 GF5CA: GSM / 4G Cellular Network Registration Failure or Failed Auto-Dialer Calls/SMS
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Console fails to register on the cellular carrier network or fails to dispatch automated voice calls and SMS messages during an alarm trigger.
02 // Non-Invasive Meter / Bench Verification
Verify the user-supplied SIM card has an active voice/SMS plan, has PIN lock disabled, is properly seated in the console SIM slot, and receives >= -95 dBm signal; check whether the unit contains a legacy 2G GSM modem operating in a region where 2G spectrum has been shut down.
Platform / OEM Cross-Reference: Original Equipment Manufacturer: Chenghelichuang Co., Ltd. / Shenzhen PGST Co., Ltd. (SZ PGST Co., Ltd.)