Daphino JY2322B-3H-NR-2P: Premature Extinction / Darkening of One Articulating Lateral Head
What this means: One of the three LED light heads (specifically a lateral articulating wing) stops illuminating while the central body and remaining wing continue operating.
60-Second Verification Check
Toggle the rear mode button through all 3 modes in darkness to confirm the lateral head remains completely unlit while the central array illuminates; inspect the ball-joint neck for visible cracking or pinched jacket insulation without disassembling the housing.
Verified Replacement Parts
Slide-On ABS Wall Mounting Bracket
Included in original retail box (2 brackets per 2-pack), but not sold separately by Daphino or third-party suppliers.
Internal 3.7V Cylindrical Lithium-Ion Cell (18650 Form Factor with Solder Tabs)
Manufacturer explicitly prohibits user replacement ('The internal lithium battery should not be replaced by the user') and housing is sealed IP65; listed strictly for hardware lineage completeness.
Why This Happens & Safety Warnings
- The internal lithium battery should not be replaced by the user. Dispose of properly at a local battery disposal center.
- Never operate the luminaire while liquid water is pooling across internal electronics; unmount and dry completely if moisture enters.
What triggers it: Manual angular adjustment of the lateral satellite heads (up to 90° pivot per side) during installation/re-aiming or sustained wind buffeting against the cantilevered wings.
What wears out inside: Repeated rotational torque or wind-induced flutter pinches, work-hardens, and fractures the internal copper interconnect wires routed through the hollow ABS ball-and-socket swivel joints or breaks their MCPCB solder terminations.
Symptom on machine: Permanent electrical open-circuit to one lateral satellite LED head, reducing total luminaire light output and eliminating wide-angle 270°/355° lateral coverage.