EVA LOGIK NST003-8; NST003: Failure to Trigger Siren on Dull Window Thud or Frame Movement
What this means: Alarm remains silent in armed standby (- or +) when subjected to dull low-frequency thuds on heavy multi-pane insulated glass or when a window sash is slid/pried without sharp glass shock.
60-Second Verification Check
Verify switch is set to High (+) and red LED blinks every 4 seconds. Inspect adhesive pad through exterior glass for air bubbles or detachment that decouples vibration. Test with a firm knuckle or coin tap.
Verified Replacement Parts
Replacement Double-Sided Acrylic Foam Mounting Tape / Pads
Inferred from planar 78 x 78 mm ABS mounting base and single-use nature of the 8 included factory pads; requires clean, degreased glass to couple shear vibrations into the sensor.
Why This Happens & Safety Warnings
- Switch unit to OFF when not in use or during window maintenance to avoid triggering the >120 dB siren at close range.
- Replace batteries immediately when the red indicator LED remains continuously ON.
What triggers it: Intruder or tester applies a dull, low-frequency thud against heavy multi-pane insulated glass (IGU), impacts the far corner of an oversized picture window (>20–30 sq ft), or quietly pries/slides the window frame without shattering glass.
What wears out inside: Heavy IGU damping and elastomeric foam attenuation filter out low-frequency shear energy before it reaches the mechanical shock transducer, while absence of a magnetic contact switch or acoustic microphone leaves frame movement unmonitored.
Symptom on machine: Alarm fails to trigger during a dull impact or non-glass-break frame entry.