Symptom Guide Model: 190NOA

Evanshow 190NOA: Complete Cessation of Motor Actuation (< 4.5 V DC Cutoff)

What this means: When internal battery voltage falls below 4.5 V DC (or collapses below 4.5 V during the <= 250 mA motor pulse), the undervoltage comparator inhibits motor actuation and drops the lock into lockout state.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Exterior lever rotates downward freely through its full arc without retracting the latch bolt when locked, and drops back into freewheeling state 5 seconds after unlocking. — By design, the exterior lever uses a freewheeling clutch architecture to prevent forced-torque over-rotation damage; the internal DC motor engages the dogging pin into the 8 mm square spindle hub only for a 5-second window following valid authentication.

Connect a regulated 5.0 V DC portable USB power bank to the exterior USB Type-C emergency port to temporarily boot logic and unlock the door, or use the mechanical override wafer key behind the exterior dust plug, then replace all 4 AAA alkaline batteries.

2

Verified Replacement Parts

#1 Most Likely Fix $4.00 - $8.00 per 4-pack

AAA 1.5 V Alkaline Primary Batteries (4x Cells)

4x 1.5 V DC AAA (LR03)… Copy Part #

Explicitly specified in operating and engineering manuals; do not substitute 1.2 V NiMH rechargeable cells (4.8 V nominal series triggers immediate low-voltage warning).

Option #2 • Secondary / Related Part $5.00 - $12.00 locksmith cut fee

Emergency Mechanical Wafer Override Keys

Custom narrow-blade… Copy Part #

2 keys included in box; duplication requires a skilled locksmith using custom narrow wafer blanks.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in biometric smart door lever lockset replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • This product is not waterproof; avoid exposure to direct sunlight or rain.
  • Do not mix fresh and depleted AAA batteries, and do not mix alkaline batteries with rechargeable NiMH or zinc-carbon cells.
Undervoltage Brownout and Logic Lockout During Motor Actuation Pulse

What triggers it: Operating past the 4.8 V low-voltage warning (~100 cycles), mixing old and new cells, using 1.2 V NiMH cells, or cold ambient exposure increasing alkaline internal resistance.

What wears out inside: When the DC clutch motor demands up to 250 mA peak actuation current, high cell impedance causes the 6.0 V rail to sag below the < 4.5 V hardware cutoff threshold, resetting the MCU or inhibiting motor drive before the dogging pin engages. Prolonged storage of depleted cells also risks KOH electrolyte leakage onto the interior PCB.

Symptom on machine: Complete electronic lockout requiring external 5.0 V USB Type-C bootstrap power or physical override key stored outside the locked room.

Cross-Compatible Platforms: Tuya Smart / Smart Life BLE mobile app integration is confirmed on sibling models 190BT, Model 003, and Model Q1, and may appear in co-mingled Store ID #237 inventory, but is absent on base standalone 190NOA / Z02.

Other Evanshow 190NOA Problems (4)
1. Quick Test 2. See Fix Parts ↓

Type any brand, model number, error code, or part number...