Symptom Guide Model: tynbdgjpl-004

LUTEC tynbdgjpl-004: Luminaire Stuck in Continuous 100% Illumination (Will Not Turn Off)

What this means: Light remains locked at 100% full brightness continuously at night (or during testing) regardless of motion timer expiration.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Light remains dimly illuminated all night at approximately 20% brightness (~700 lumens) when no motion is present. — When Dusk-to-Dawn (D2D) mode is selected, the luminaire is engineered to maintain a continuous 20% ambient standby glow from dusk until dawn, ramping to 100% (3,500 lm) only when motion is detected.

1) Perform power-cycle reset: turn wall switch OFF for at least 10-30 seconds, then turn back ON to clear inadvertent Manual Override latching caused by power flickers. 2) Check underside slide switch to ensure unit is not left in 'Test' mode with continuous motion. 3) Inspect PIR dome for spider webs or HVAC heat plumes causing constant re-triggering.

2

Verified Replacement Parts

#1 Most Likely Fix Check Live Stock

Extended Center Mounting Machine Screw (M4x0.7)

Metric M4 x 0.7 mm… Copy Part #

Confirmed factory screw specification is M4x35 threading into the universal crossbar center bore; head diameter must fit inside the central canopy counterbore to allow the silicone rubber plug to seat.

Option #2 • Budget Aftermarket Check Live Stock

Universal 4-Inch Round/Octagonal Junction Box Crossbar Bracket

Standard 4.0-inch… Copy Part #

Matches standard North American 4.0 to 4.13-inch exterior round/octagonal electrical junction boxes.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in outdoor motion sensor led security floodlight replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • Electrical installation, circuit diagnosis, and fixture wiring must be performed in accordance with local electrical codes; always disconnect power at the circuit breaker or fuse box before installation or servicing.
  • The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
Inadvertent Manual Override Latching via Power-Line Flickers

What triggers it: Momentary utility grid voltage dropouts, recloser events, or rapid accidental wall switch toggling.

What wears out inside: Internal AC power-cycle state-detection circuit registers two power interruptions within a 3-second window (equivalent to OFF-ON-OFF-ON) and latches the state machine into 6-hour Manual Override mode.

Symptom on machine: Luminaire remains locked at 100% illumination (3,500 lm) continuously until timeout, dawn reset, or manual power-cycling by the owner.

Nuisance PIR False Triggering from Thermal Plumes, Foliage, or Spiderwebs

What triggers it: High sensitivity setting ('H' = 69 ft) combined with wind-blown foliage, HVAC/dryer exhaust plumes, street traffic, or spiderwebs moving across the Fresnel dome.

What wears out inside: Rapid differential infrared shifts (delta T) across multi-zone Fresnel segments exceed the pyroelectric amplifier threshold, registering as human motion.

Symptom on machine: Repeated nuisance 100% floodlight cycling throughout the night, disturbing household or neighbors.

Cross-Compatible Platforms: Corporate manufacturing parent is Ningbo UTEC Electric Co., Ltd. (Yuyao, Ningbo, China); US distributor and warrantor is LUTEC USA LLC (Troutman, NC).