PGST A02F: Failure to Dispatch 4G SMS Alerts or Sequential Voice Phone Calls
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
During an active alarm state, the host console triggers the local siren but fails to send SMS messages or dial the 5 preset emergency telephone numbers.
02 // Non-Invasive Meter / Bench Verification
Verify that a Micro/Nano SIM card is properly seated in the host slot, has an active funded balance, is provisioned for standard voice calling and SMS (not a data-only IoT SIM), has SIM PIN lock disabled, and shows cellular signal bars on the host display.
Platform / OEM Cross-Reference: Sub-1 GHz peripheral fabric operates on 433.92 MHz carrier frequency using ASK/OOK modulation and fixed-code eV1527 framing.