FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: A02F TIER 1–2 BENCH DIY

PGST A02F: Failure to Dispatch 4G SMS Alerts or Sequential Voice Phone Calls

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

During an active alarm state, the host console triggers the local siren but fails to send SMS messages or dial the 5 preset emergency telephone numbers.

02 // Non-Invasive Meter / Bench Verification

Verify that a Micro/Nano SIM card is properly seated in the host slot, has an active funded balance, is provisioned for standard voice calling and SMS (not a data-only IoT SIM), has SIM PIN lock disabled, and shows cellular signal bars on the host display.

Platform / OEM Cross-Reference: Sub-1 GHz peripheral fabric operates on 433.92 MHz carrier frequency using ASK/OOK modulation and fixed-code eV1527 framing.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
universal aftermarket part
Isolated Match
110-120V AC 60Hz North… 5.0V DC USB-A/C Power Supply Wall Adapter
Confirmed 5.0V DC USB-C host input rating in A02F user manual and device specifications; must provide clean, ripple-free regulated 5.0V DC power to prevent capacitive key instability.
$5.00 - $10.00
Part 2
universal aftermarket part
Isolated Match
Standard USB 2.0 Type-A… USB Type-A to USB Type-C Power Cable
Matches host USB Type-C DC power receptacle; conductor gauge must be sufficient to prevent voltage drop over 1.0-2.0 m runs.
$3.00 - $6.00
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified wireless diy intrusion detection and alarm system replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSLithium-Ion

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Do not use 3.6V rechargeable LIR2450 cells in PB-68 contact sensors designed for 3.0V CR2450 primary lithium cells, and do not mix spent and fresh batteries or insert with reverse polarity.
  • Do not use chemical solvents, alcohol, ammonia, or abrasive pads on P92R PIR HDPE Fresnel lenses.

Root Failure Mechanism: 4G LTE/GSM Cellular SMS and Voice Dialout Failure due to SIM Provisioning or Band IncompatibilityClick to spotlight part ↑

01 // Trigger ConditionInsertion of a data-only IoT SIM, expiration of prepaid SIM balance, enabled SIM PIN lock, or carrier sunsetting of legacy voice/SMS fallback bands not supported by the undocumented baseband modem.
02 // Degradation PhysicsCellular baseband modem cannot establish circuit-switched/VoLTE voice calls or SMS routing on the local carrier tower.
03 // Lockout / ImpactSecondary cellular WAN alert pathway fails silently during an intrusion or Wi-Fi outage, leaving the system dependent solely on home Wi-Fi and local siren.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Host console cannot detect or authenticate to 5.0 GHz Wi-Fi SSIDs during setup.: The embedded Wi-Fi SoC is hardware-designed exclusively for 2.4 GHz IEEE 802.11b/g/n (2412-2462 MHz) and contains no 5.0 GHz RF transceiver circuitry. (True fault when: Indicates an actual hardware or firmware fault only if the console fails to pair with a dedicated, strong 2.4 GHz 802.11b/g/n SSID using WPA/WPA2 security in close proximity to the router.)
False-Alarm Check — Internal backup battery depletes in under 1 hour when AC mains power is disconnected and the alarm siren and cellular dialer are actively triggered.: The 8-hour rating applies strictly to quiescent standby conditions; driving the 120 dB piezoelectric transducer and 4G cellular transmitter draws significantly higher current that rapidly drains the compact internal LiPo pouch cell. (True fault when: Indicates internal LiPo cell aging or failure if quiescent standby runtime (with no alarm sounding) drops from ~8 hours to under 30 minutes upon AC mains loss.)

Other PGST A02F Diagnostic Sheets