Observe correct +/- battery polarity diagrams embossed in the battery bay when inserting two 1.5 V AAA alkaline cells.
Do not mix fresh and depleted batteries, and remove depleted batteries promptly to prevent electrolyte leakage.
Before Ordering Parts: Normal Operation vs. True Fault
False-Alarm Check — After detecting motion once, the sensor stops flashing its red LED and stops triggering the alarm host when a user waves or walks in front of it immediately afterward.: When internal jumper J4 is set to Sleep Mode (power-saving mode), the CMOS processor enforces a multi-minute lockout timer after a trigger event to prevent continuous 25 mA RF bursts in high-traffic rooms and preserve AAA battery life. (True fault when: Indicates a fault only if the sensor still fails to trigger after the room has been completely vacant for more than 5 minutes, or fails to trigger when jumper J4 is explicitly set to Test Mode with fresh 1.5 V AAA alkaline cells installed.)
False-Alarm Check — The sensor does not respond properly to motion or trigger the host panel during the first 30 seconds immediately following battery insertion.: The internal analog pyroelectric amplifier and CMOS comparator require a mandatory 30-second power-on thermal/electrical stabilization and self-check period (concluded by 2 LED flashes) before arming. (True fault when: Indicates a fault if the unit never completes initialization or shows zero LED activity after 60 seconds with verified 3.0 V DC supply.)