PGST PA-92R: Front Red LED Flashes Twice (2 Flashes)

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Indicates completion of the 30-second power-on initialization and self-check cycle, transitioning into active sensing state.

02 // Non-Invasive Meter / Bench Verification

Wait 30 seconds after inserting two fresh 1.5 V AAA alkaline cells and observe the double flash before commencing walk-testing.

Platform / OEM Cross-Reference: PGST alarm panels (models PG-103, PG-105, PG-106, PG-107, PG-108, PG-109, PG-500) natively support enrollment of this sensor via 433.92 MHz RF learning.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
PA-92R Complete Replacement PGST Wireless PIR Motion Sensor Unit (PA-92R / PA92-1)
Exact OEM whole-unit replacement; buyer must confirm 433.92 MHz EV1527 specification rather than 315 MHz or 868 MHz regional variants.
$12.00 - $15.99 USD
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified indoor sub ghz wireless pir motion detector replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSSilicone

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Observe correct +/- battery polarity diagrams embossed in the battery bay when inserting two 1.5 V AAA alkaline cells.
  • Do not mix fresh and depleted batteries, and remove depleted batteries promptly to prevent electrolyte leakage.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — After detecting motion once, the sensor stops flashing its red LED and stops triggering the alarm host when a user waves or walks in front of it immediately afterward.: When internal jumper J4 is set to Sleep Mode (power-saving mode), the CMOS processor enforces a multi-minute lockout timer after a trigger event to prevent continuous 25 mA RF bursts in high-traffic rooms and preserve AAA battery life. (True fault when: Indicates a fault only if the sensor still fails to trigger after the room has been completely vacant for more than 5 minutes, or fails to trigger when jumper J4 is explicitly set to Test Mode with fresh 1.5 V AAA alkaline cells installed.)
False-Alarm Check — The sensor does not respond properly to motion or trigger the host panel during the first 30 seconds immediately following battery insertion.: The internal analog pyroelectric amplifier and CMOS comparator require a mandatory 30-second power-on thermal/electrical stabilization and self-check period (concluded by 2 LED flashes) before arming. (True fault when: Indicates a fault if the unit never completes initialization or shows zero LED activity after 60 seconds with verified 3.0 V DC supply.)