Symptom Guide Model: PG-107

PGST PG-107: Unoccupied Zone Intrusion Alarm on PIR Motion Detector

What this means: PIR motion detector trips the system alarm while armed with no human intruder present.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Bundled PA-92 wireless PIR motion detector stops flashing or transmitting repeated motion triggers immediately after detecting movement. — The PA-92 PIR sensor incorporates a deliberate 3-minute sleep timer circuit after triggering to prevent rapid depletion of its two AAA alkaline batteries in high-traffic areas.

Check whether the PIR sensor lens faces HVAC vents, radiators, sunlit windows, or pet traffic; wipe the external HDPE Fresnel lens gently with a dry lint-free microfiber cloth and re-angle at 1.8-2.2m height.

2

Verified Replacement Parts

#1 Most Likely Fix Check Live Stock

PGST PA-92 / 433.92 MHz EV1527 Wireless PIR Motion Detector

PA-92 Copy Part #

Pairs directly with the PG-107 host via the on-screen zone learning menu.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in wireless smart home security alarm system kit replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • Do not power off the host base station or disconnect Wi-Fi while writing OTA firmware updates.
  • Do not intermix discharged and fresh battery cells, and do not use 1.2V NiMH rechargeable or zinc-carbon batteries in PIR motion detectors.
PIR Volumetric Motion Detector False Alarms from Convective Thermal Plumes or Lens Degradation

What triggers it: Mounting PIR detectors near HVAC vents, radiators, or sunlit windows, or cleaning the HDPE lens with chemical solvents or abrasive cloths.

What wears out inside: Moving thermal air currents shift infrared differentials across the segmented HDPE Fresnel lens zones onto the dual-element pyroelectric sensor, generating false voltage spikes; solvent/abrasive damage scatters IR radiation and degrades sensitivity.

Symptom on machine: Nuisance siren activations (100-120 dB) and false intrusion alerts while the system is armed, or reduced 8-12m detection range if optics are abraded.

Other PGST PG-107 Problems (8)