Ring 4K11S7-0EN0: Base Station Continuous AC/Battery Trouble Fault or Unexpected Reboot
What this means: Base Station reports persistent battery trouble after multi-year service or reboots under peak load (such as cellular transmission).
60-Second Verification Check
Verify the external power supply is the rated 5.0V DC, 2.5A center-positive adapter (DSA-13PFJ-05) securely seated in the rear barrel jack; if the unit fails to hold backup charge during AC disconnect after 3–6 years, the internal sealed pouch cell has degraded.
Verified Replacement Parts
Base Station 5V 2.5A External Switching Power Adapter
Confirmed in Ring SDoC and hardware label inspection. Using an under-rated current supply causes Base Station reboots during LTE cellular transmission.
Why This Happens & Safety Warnings
- CAUTION: To reduce the risk of electrical shock, DO NOT open the unit. There are no user serviceable parts inside the unit. Refer to customer support for any repairs.
- Opening the Base Station, Keypad, or Range Extender voids the limited manufacturer warranty and compromises regulatory compliance.
What triggers it: Continuous 24/7/365 AC mains connection holding internal LiCoO2 polymer pouch cells at float charge under indoor ambient temperatures.
What wears out inside: Sustained float voltage (managed by TI BQ25892 in Base Station) and ambient heat drive electrolyte oxidation, internal impedance growth, capacity loss, and gas generation (pouch swelling).
Symptom on machine: Emergency blackout runtime drops from ~24 hours to minutes, devices report persistent battery trouble faults, or swollen cells stress sealed enclosures, requiring whole-unit replacement due to non-user-serviceable design.
Cross-Compatible Platforms: Model designations bearing the prefix 5B28Sx (e.g., 5B28S5, 5B28S7, 5B28S8) designate UK/EU regional hardware variants tuned to 868.4 MHz Z-Wave and 230V mains; their radio characteristics must not be transferred to the US B07ZDTXJ93 SKU.