SANSI C2440-MW-30W: Continuous Flickering / Rapid On-Off Strobing at Night
What this means: Luminaire repeatedly turns on, immediately shuts off, and re-triggers in a continuous strobing loop during nighttime operation, or buzzes/strobes erratically.
60-Second Verification Check
1. Verify the branch circuit does not use a dimmer switch. 2. Reposition both lamp heads away from the PIR sensor housing (maintaining at least 25 mm clearance) and away from reflective surfaces. 3. Adjust the 'Lux' rotary dial to prevent reflected light from crossing the dawn shut-off threshold.
Verified Replacement Parts
Internal Switched-Mode AC-DC Driver Board
Proprietary SANSI integrated constant-current driver IC potted inside the rear housing; manufacturer explicitly states the whole luminaire must be replaced upon driver failure.
Why This Happens & Safety Warnings
- When the light source or power supply driver reaches its end of life, the whole luminaire shall be replaced.
- Opening any part of the housing, lamp heads, or sensor assembly is prohibited by manufacturer safety documentation and voids the ETL listing and IP65 seal.
What triggers it: Lamp heads aimed downward toward the sensor stalk (<25 mm clearance) or toward adjacent light-colored walls/eaves, combined with a low 'Lux' potentiometer threshold setting.
What wears out inside: High-flux 4,000-lumen output reflects directly into the CDS ambient photocell; the control logic interprets the reflected light as dawn (>Lux threshold) and cuts power; once dark, the sensor re-arms and re-triggers immediately, locking the fixture into a closed-loop oscillation.
Symptom on machine: Severe nighttime strobing/cycling that renders security lighting unusable, causes neighbor nuisance complaints, and subjects the switched-mode driver to repetitive inrush cycling.
What triggers it: Installing the luminaire on a branch circuit controlled by a TRIAC, ELV, or smart phase-cut wall dimmer switch.
What wears out inside: Chopped AC input waveforms cause severe dv/dt spikes and voltage starvation across the non-dimmable constant-current SMPS input rectifier and PIR control rail, overheating switching components.
Symptom on machine: Immediate erratic strobing, audible transformer buzz, erratic sensor logic, and permanent burnout of the non-replaceable potted driver.