Wait 3 minutes (180 seconds) without pressing buttons for the tamper lockout timer to expire, or use the physical mechanical override key in the cylinder for immediate entry.
Platform / OEM Cross-Reference: Veise operates under parent OEM Shenzhen Kaadas Intelligent Technology Co., Ltd. (Kaadas Group, with affiliated entities Shenzhen Fengyu Technology Co., Ltd. and Shenzhen Xinyan Technology Co., Ltd.), sharing core electronics and mechanical platforms across KS, RZ, and VE series locks.
Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN
Role
OEM MPN / Spec
Component & Fitment Notes
Est. Street
Check Stock
Part 1 accessory Isolated Match
Schlage SC1 5-Pin key…
Duplicate Mechanical Override Keys (5-Pin Key Blank) 2 factory keys are included with the SKU; duplication on SC1 5-pin blanks is supported by Veise residential brand-family specifications and should be performed before losing both factory keys.
Material / Sensor Nodes:ABSBRASSCarbon SteelEepromSilicone
Failure Physics & Causal Isolation
Safety & Disassembly Lockouts:
Do not use lacquer thinner, caustic soaps, abrasive cleaners, or metal polishes on the exterior finish; clean with a soft damp cloth only.
Do not use wet oil-based lubricants (such as WD-40, silicone spray, or mineral oil) on the deadbolt latch; use only dry graphite lubricant.
Root Failure Mechanism: Temporary 3-Minute Electronic Keypad Freeze from 10 Consecutive Invalid PIN EntriesClick to spotlight part ↑
01 // Trigger ConditionTen consecutive incorrect PIN codes entered on the keypad (e.g., children playing with buttons, mistyped decoy strings exceeding 16 digits, or unauthorized code guessing).
02 // Degradation PhysicsOn-board MCU security counter triggers an intentional 180-second lockout state during which all keypad matrix inputs are ignored.
03 // Lockout / ImpactTemporary 3-minute delay in electronic keypad entry; immediately bypassable via physical mechanical key.
Before Ordering Parts: Normal Operation vs. True Fault
False-Alarm Check — The deadbolt automatically extends its 1-inch steel bolt after 10 to 99 seconds even while the door is standing wide open.: The KS01B does not incorporate a door-position sensor; its auto-lock function operates strictly on an open-loop countdown timer (configurable from 10 to 99 seconds, default 30 seconds when enabled) that fires regardless of door position. (True fault when: Indicates a fault only if auto-lock has been explicitly disabled via keypad programming (or passage/vacation mode settings) and the bolt still throws automatically.)
False-Alarm Check — The exterior keypad stops accepting PIN inputs and appears locked up for 3 minutes.: Intentional anti-tamper security firmware freezes keypad input for 3 minutes (180 seconds) after 10 consecutive wrong PIN entries to deter brute-force code guessing. (True fault when: Indicates a fault if the keypad remains unresponsive after more than 3 minutes have elapsed and replacing the 4x AA alkaline batteries does not restore operation.)