XUK PG-107: Unprovoked PIR Motion Alarm Triggered While Premises Vacant
What this means: Siren activates and hub logs a motion sensor zone intrusion event when no human intruder is present.
60-Second Verification Check
Inspect PIR mounting angle and field of view for HVAC vents, radiators, direct sunlight across floors, or pets moving near the sensor elevation; perform a walk-test in test mode.
Verified Replacement Parts
433.92 MHz EV1527 Wireless PIR Motion Detector
Interoperable with the PG-107 433.92 MHz EV1527 receiver bus; ensure mounting bracket allows proper 2.0-2.2 m height vertical tilt alignment.
Why This Happens & Safety Warnings
- Opening or unmounting the central console while armed or powered triggers the rear spring-loaded anti-tamper switch and activates the siren unless disarmed or placed in test mode.
- Do not use abrasive scouring powders, alcohol solvents, chemical sprays, or excess liquid on the console touchscreen or PIR Fresnel lens.
What triggers it: HVAC system cycling, direct sunlight moving across floors, or pets moving through the detection zone.
What wears out inside: The basic dual-element pyroelectric sensor behind the segmented polyethylene Fresnel lens lacks advanced digital signal processing (DSP) temperature compensation; rapid convective thermal gradients trigger false intrusion state transitions, while high ambient temperatures (34°C-37°C) narrow contrast and increase miss rates.
Symptom on machine: Unexpected 100-110 dB siren activations and emergency phone alerts while premises are vacant, causing nuisance disturbance and eroding user trust.