Symptom Guide Model: PG-107

XUK PG-107: Unprovoked PIR Motion Alarm Triggered While Premises Vacant

What this means: Siren activates and hub logs a motion sensor zone intrusion event when no human intruder is present.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Siren blasts immediately when the owner lifts or slides the central console off its rear wall-mounting bracket to insert a SIM card or relocate the unit. — The rear chassis incorporates a spring-loaded anti-tamper microswitch designed to trigger an immediate alarm whenever the backplate separates from the console while powered.

Inspect PIR mounting angle and field of view for HVAC vents, radiators, direct sunlight across floors, or pets moving near the sensor elevation; perform a walk-test in test mode.

2

Verified Replacement Parts

#1 Most Likely Fix $8.00-$15.00 per sensor

433.92 MHz EV1527 Wireless PIR Motion Detector

433.92 MHz EV1527… Copy Part #

Interoperable with the PG-107 433.92 MHz EV1527 receiver bus; ensure mounting bracket allows proper 2.0-2.2 m height vertical tilt alignment.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in wireless home security alarm system replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • Opening or unmounting the central console while armed or powered triggers the rear spring-loaded anti-tamper switch and activates the siren unless disarmed or placed in test mode.
  • Do not use abrasive scouring powders, alcohol solvents, chemical sprays, or excess liquid on the console touchscreen or PIR Fresnel lens.
Wireless PIR Motion Detector False Alarms from Thermal Drafts and Ambient Gradients

What triggers it: HVAC system cycling, direct sunlight moving across floors, or pets moving through the detection zone.

What wears out inside: The basic dual-element pyroelectric sensor behind the segmented polyethylene Fresnel lens lacks advanced digital signal processing (DSP) temperature compensation; rapid convective thermal gradients trigger false intrusion state transitions, while high ambient temperatures (34°C-37°C) narrow contrast and increase miss rates.

Symptom on machine: Unexpected 100-110 dB siren activations and emergency phone alerts while premises are vacant, causing nuisance disturbance and eroding user trust.