Error Code Model: YRD410-WF1-BSP

Yale Security YRD410-WF1-BSP: Motor Stall / 'Deadbolt Jammed' Alert and Keypad Error Flash

What this means: Internal motor fails to complete full deadbolt extension or retraction travel due to mechanical obstruction or torque limit trip, emitting acoustic buzzer alerts, LED flashes, and app 'Deadbolt Jammed' notifications.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Proximity Auto-Unlock fails to trigger or delays unlocking when the owner approaches the door with a smartphone. — Auto-Unlock relies on smartphone iOS/Android background location geofencing and mobile BLE scanning; aggressive mobile OS battery-saver policies suspend background app tasks, preventing timely handshakes.

Test lock cycle with the door swung open; if the bolt throws smoothly when open but stalls when closed, inspect the frame strike plate alignment, weatherstripping compression, and verify the strike pocket is at least 1.0 in (25 mm) deep, then run the Lock Calibration routine in the Yale Access app.

2

Verified Replacement Parts

#1 Most Likely Fix ~$13.95–$16.95

Yale OEM Adjustable Deadbolt Latch Core (Round Corner)

1 in x 2-1/4 in Round… Copy Part #

Direct OEM mechanical latch replacement verified in Yale parts catalog.

Option #2 • Secondary / Related Part ~$5.90–$8.34

Yale OEM Replacement Drive-In Deadbolt Latch Core

1.0 in diameter… Copy Part #

Official Yale replacement part for doors with un-mortised circular edge bores (common on steel/metal entry doors).

Repair Cost Too Close to a New Unit? Compare top-rated drop-in smart deadbolt lock replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • Always remove all four AA batteries before inserting, removing, or reseating the Yale Smart Module (AYR-MOD-WF1-USA) to prevent UART bus latch-up or permanent logic damage.
  • Unauthorized disassembly of the factory-sealed interior electromechanical motor/gearbox assembly voids the manufacturer warranty and risks breaking plastic snap tabs or dislodging geartrain pins.
Electromechanical Drivetrain Stall and 'Deadbolt Jammed' Fault from Strike Friction

What triggers it: Seasonal door frame settling, warped door stiles, tight weatherstripping push-back, or an insufficiently deep (<1.0 in) jamb strike pocket.

What wears out inside: Lateral side-load friction on the tapered deadbolt bolt or axial obstruction in the strike pocket exceeds the internal brushed DC micro-motor torque limit or prevents reaching the internal position limit switches, causing the mainboard H-bridge controller to abort travel.

Symptom on machine: Failure of automated or remote locking, leaving the perimeter unsecured, accompanied by elevated motor current draw that accelerates battery drain and subjects internal reduction gears to wear.

Cross-Compatible Platforms: Operating temperature ratings of -30°C to 60°C (exterior) and -15°C to 70°C (interior) apply across the Assure Lock 2 family.

Other Yale Security YRD410-WF1-BSP Problems (4)
1. Quick Test 2. See Fix Parts ↓

Type any brand, model number, error code, or part number...