ImoLaza ET Master ET Master 06: Controller flashes red during schedule or shuts down when specific zone activates
What this means: Indicates an overcurrent condition, typically caused by a shorted 24VAC solenoid coil or damaged buried field wire splice.
60-Second Verification Check
Unplug transformer 30s, reconnect, run each zone manually for 10s; if unit trips on a specific zone, inspect/replace that solenoid valve (normal coil ~20–60 Ω).
Verified Replacement Parts
24VAC Solenoid Valves (External)
Must be standard 24VAC solenoid valves compatible with irrigation systems.
Why This Happens & Safety Warnings
What triggers it: Activation of a specific irrigation zone
What wears out inside: Buried wire nick or shorted solenoid coil causes overcurrent (>1000mA) on the 24VAC output.
Symptom on machine: Milliamp sensor trips, controller flashes red LED, and shuts down the affected zone or entire unit.
Cross-Compatible Platforms: Intelligent Watering Decision Model™ (ET Smart Schedule, New Grass Schedule up to 24 start times, Fixed Schedule, up to 16 schedules, 99-minute max zone duration, Smart Cycle & Soak, sunrise/sunset offset).