Symptom Guide Model: ET Master 06

ImoLaza ET Master ET Master 06: Controller flashes red during schedule or shuts down when specific zone activates

What this means: Indicates an overcurrent condition, typically caused by a shorted 24VAC solenoid coil or damaged buried field wire splice.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Silent operation; mild warmth on external plug-in wall transformer — Solid-state switching is silent. Mild warmth at the wall-plug transformer is normal due to energy conversion losses.

Unplug transformer 30s, reconnect, run each zone manually for 10s; if unit trips on a specific zone, inspect/replace that solenoid valve (normal coil ~20–60 Ω).

Target: 24VACTarget: 20–60 Ω
2

Verified Replacement Parts

#1 Most Likely Fix $15–$35 each

24VAC Solenoid Valves (External)

Standard 24VAC 60Hz… Copy Part #

Must be standard 24VAC solenoid valves compatible with irrigation systems.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in L13 smart wifi sprinkler controllers replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Zone Short-Circuit Shutdown

What triggers it: Activation of a specific irrigation zone

What wears out inside: Buried wire nick or shorted solenoid coil causes overcurrent (>1000mA) on the 24VAC output.

Symptom on machine: Milliamp sensor trips, controller flashes red LED, and shuts down the affected zone or entire unit.

Cross-Compatible Platforms: Intelligent Watering Decision Model™ (ET Smart Schedule, New Grass Schedule up to 24 start times, Fixed Schedule, up to 16 schedules, 99-minute max zone duration, Smart Cycle & Soak, sunrise/sunset offset).