Symptom Guide
Model: DVRF-BDG-1DP-A
Lutron DVRF-BDG-1DP-A: Hub Offline / Blinking LED
What this means: Lutron App shows 'Hub Disconnected' or the hub's status LED is blinking.
1
60-Second Verification Check
⚠ Quick Check Before Buying Parts: LED Ghosting (Dim Glow When Off) — This is a normal physical consequence of the 2-wire (no-neutral) dimmer design, which draws a small leakage current through the load to power its internal electronics. Ultra-low-wattage LED drivers can rectify this small current, causing a faint glow.
Verify Ethernet cable connection, router link light, and 5V micro-USB power supply. Check internet connectivity.
2
Verified Replacement Parts
#1 Most Likely Fix
Generic: ~$8–$12
Smart Hub Power Supply
Standardized micro-USB connector and common voltage/current rating. Must be UL-listed for safety.
Repair Cost Too Close to a New Unit?
Compare top-rated drop-in Smart In Wall Lighting Dimmer & RF Hub Starter Kit replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
- Dimmer Internal PCB (DVRF-6L) & Hub Internal PCB (L-BDG2): Ultrasonically welded or snap-locked UL-listed enclosures designed to prevent accidental contact with 120V live mains and preserve UL 1472 safety certification. Not field-serviceable at the component level; failed units are replaced as complete modules.