MHCOZY 1CHZIGDC: Relay Stuck Closed (Contact Welding)
What this means: Load stays permanently ON even when app/LED shows OFF.
60-Second Verification Check
Continuity persists across COM-NO with power removed.
Verified Replacement Parts
Internal Electromechanical SPDT PCB Relay
Independent technician bench reference. Requires matching measured coil voltage (5V vs. 12V) and pin pitch on PCB.
External Pilot Contactor (Load Isolation)
Recommended to offload inductive motors or high-inrush lighting from the micro-relay, preventing premature failure.
Why This Happens & Safety Warnings
What triggers it: Switching high-inrush capacitive or inductive loads (e.g., motors, LED drivers)
What wears out inside: High current arcs across thin silver-alloy contacts, causing localized melting and permanent welding of contacts in the closed position.
Symptom on machine: Load remains permanently ON, module becomes unresponsive to OFF commands, potential fire hazard if load is not designed for continuous operation.
Cross-Compatible Platforms: Songle SRD-series relay reliability limits, ULN2003 driver architecture, and -20°C to 70°C / 40–80% RH manuals are derived from MHCOZY brand-family documentation (ZG-001, ZIGDC32, and Hubitat/HA teardowns).