FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: GS110TPv3 TIER 1–2 BENCH DIY

NETGEAR GS110TPv3: PoE Max LED = Solid Yellow

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Indicates less than 7W PoE budget remaining out of 55W total. Newly connected Powered Devices (PDs) may fail to power up or experience power denial.

02 // Non-Invasive Meter / Bench Verification

Check per-port wattage draw in Web UI and set PoE port priority. Reduce total PoE load by disconnecting non-essential PDs or replacing with lower-power alternatives.

Platform / OEM Cross-Reference: Shares Realtek rtl838x platform family and HIG documentation with GS108Tv3 (non-PoE, 12V 1.0A) and GS110TPP (120W PoE+, 10 copper ports, no SFP).

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
332-11059-04 External 54V 1.25A AC-DC Power Adapter
Matches OEM specifications for voltage, current, power, and barrel connector dimensions. UL-listing ensures safety compliance.
OEM: ~$45–$70; Generic UL-listed: ~$25–$35
Part 2
accessory
Isolated Match
AGM731F 1G SFP Multi-Mode Fiber Transceiver (SX)
Must be MSA-compliant and compatible with NETGEAR's SFP coding for optimal interoperability.
OEM: ~$35–$55; MSA Generic: ~$10–$18
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified l2 l2 plus smart managed gigabit poe plus ethernet switch replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSCopper

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Official Hardware Installation Guide mandates indoor-only use and external surge protection for outdoor cables, implying that internal components are not designed for user-level repair from such damage.
  • The external power brick is ultrasonically welded for safety, making it non-serviceable (TIER_4).

Root Failure Mechanism: PoE Budget Starvation / PD BrownoutClick to spotlight part ↑

01 // Trigger ConditionConnecting multiple high-draw 802.3at PDs (e.g., 3+ PoE+ PTZ cameras/APs)
02 // Degradation PhysicsCombined power draw exceeds the 55W total budget, triggering the PoE Max yellow LED and causing the PSE controller to deny power to lower-priority ports or new connections.
03 // Lockout / ImpactPowered Devices fail to boot, intermittently lose power, or operate with reduced functionality.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Warm-to-touch metal chassis with complete silence (0 dBA): The switch is designed for fanless passive cooling, dissipating heat through its metal enclosure and internal heatsinks. A warm chassis is normal, especially under PoE load. (True fault when: Burning odor, scorching surface temperature, or visible chassis deformation, indicating blocked vents or an internal short circuit.)
False-Alarm Check — PoE Max LED illuminates solid yellow: The solid yellow PoE Max LED is a normal warning indicator that less than 7W of the 55W PoE budget remains, signaling that new high-power PDs may not receive power. It is a protection mechanism, not a fault. (True fault when: If the LED is solid yellow and no PoE devices are connected, or if it remains yellow despite significantly reducing PoE load, it could indicate a fault with the PoE PSE controller or power supply.)

Other NETGEAR GS110TPv3 Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...