FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: HS2 TIER 1–2 BENCH DIY

Onvis HS2: Multi-second delay or dropped presses at distance

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Delayed or failed execution of button presses, especially when the device is far from the Home Hub or Thread Border Router.

02 // Non-Invasive Meter / Bench Verification

Check Eve or Onvis app to confirm Thread transport (not BLE 5.0); add a mains-powered Thread router if signal is weak.

Platform / OEM Cross-Reference: Shares Onvis Home iOS app OTA firmware update workflow and Shenzhen ChampOn Technology HomeKit-over-Thread platform architecture with Onvis CT3 and SMS2.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
routine consumable
Isolated Match
IEC CR2450 (24.5 mm dia x… CR2450 3V Lithium Coin Cell
Standard IEC chemistry and dimensions for CR2450 coin cells.
Generic: $2–$5 per cell
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified wireless scene controller replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABS

Failure Physics & Causal Isolation

Root Failure Mechanism: Premature CR2450 Battery DepletionClick to spotlight part ↑

01 // Trigger ConditionWeak Thread signal, BLE fallback mode, or frequent button actuations.
02 // Degradation PhysicsIncreased radio wake duration and TX retries, or accelerated self-discharge due to heat, leading to higher average current draw.
03 // Lockout / Impact650 mAh coin cell drains well before 1-year rated standby life.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Side LED flashes White (single press), Green (double press), or Blue (long press): This is normal operation confirming press registration and the type of press (single, double, long). (True fault when: Absence of LED flash when a button is pressed indicates a dead battery or a switch fault.)
False-Alarm Check — LED blinks Red, Green, and Blue once; device drops from HomeKit and loses all 15 scenes: Holding the center key for approximately 15 seconds is the intentional factory reset procedure. (True fault when: If the device resets without the center button being held, it could indicate a hardware fault with the button or firmware.)

Other Onvis HS2 Diagnostic Sheets