RODOT KR2301-1: Device Dead / No LED / No Click
What this means: Complete loss of power, no indicator lights, and no response to any input.
60-Second Verification Check
Confirm 100–240V AC across L-In and N-In with multimeter; if mains present and LED dead, internal SMPS stage has failed.
Verified Replacement Parts
Complete Replacement Module (KR2301-1)
Must match electrical ratings (16A, 100-240V AC), form factor, and safety certifications for the intended installation.
Why This Happens & Safety Warnings
What triggers it: Continuous 24/7 operation inside a warm, unventilated wall box.
What wears out inside: Elevated capacitor core temperature accelerates electrolyte dry-out, increasing Equivalent Series Resistance (ESR) and reducing capacitance.
Symptom on machine: Unstable power supply leads to Wi-Fi drops, device reboots, relay chattering, or complete power failure (device dead).
What triggers it: Lightning-induced voltage spikes or utility-switching transients on the AC mains line.
What wears out inside: Voltage spikes exceed the breakdown voltage of the compact non-isolated buck converter, leading to component failure (e.g., shorting of SMPS IC, opening of fusible resistor).
Symptom on machine: Complete loss of device functionality (device dead).
Cross-Compatible Platforms: Shares the standard 6-terminal Tuya / Smart Life 16A mini Wi-Fi switch mechanical and electrical architecture (N-In, N-Out, L-In, L-Out, S1, S2).